A reverse osmosis system holds treated water in a small pressurized storage tank, and that tank pushes the water to the faucet when you open it. Inside is a flexible bladder with a cushion of air on one side. When that air charge drops, or the bladder fails, the tank stops delivering a steady flow. The first sign is often a sputter or spit from the faucet after the tank has been used, long before the water quality changes.
Know the early signs
Watch for a faucet that runs strongly at first and then sputters, spits air, or slows to a trickle once the tank is partly empty. Notice whether the tank refills more slowly than it used to, or whether the faucet works well when you first open it and then loses force after a few glasses. A tank that feels heavy and fully charged with water when it is supposed to be empty is another sign, because it means the bladder has taken on water where air should be.
Check the air charge with the system drained
To check the tank, shut off the water supply to the reverse osmosis unit, then open the faucet until the tank is fully drained and the flow stops. With the tank empty, use a tire-style gauge on the air valve at the top of the tank and compare the reading with the figure printed on the tank or in the manufacturer's manual. Do not guess the target value. If the reading is well below the manufacturer's figure, the tank needs attention. Close the faucet, turn the supply back on, and let the system refill before you use it again.
Do not open the tank to fix it
The bladder and its air charge are under pressure. If the tank reading is wrong, or the tank will not hold air, a repair or replacement is a job for the installer or a qualified technician. Ask the provider whether the tank is covered under the warranty, and whether replacing the tank or its bladder is a labor charge or a parts charge.
Questions to ask before you buy or service
- What is the target air charge for the tank you are installing, and where is that figure printed?
- How is the tank tested during a maintenance visit?
- If the bladder fails, is the tank replaced whole or can the bladder be swapped?
- Is the tank included in the warranty, and who pays the labor if it fails?
- What will the provider check on the next visit, and will they write the tank reading down?
A tank problem is easy to misread as a filter problem. If the faucet sputters but the water still tastes clean, check the tank before you replace any filter.